Electrical Properties

Models for material electrical properties are simple or specialized, being very applicationoriented. The primary need for modeling electrical potential effects are to activate mass transport mechanisms that are charge-dependent.

Electrical Conductivity

Electrical Conductivity = {model_name} {float} []

Description / Usage

This required card is used to specify the model for electrical conductivity. There are currently three options, so {model_name} can be either CONSTANT, ELECTRONEUTRALITY_FICKIAN or ELECTRONEUTRALITY_SM. Definitions of the input parameters are as follows:

CONSTANT

Name of the model for constant electrical conductivity. <float> - the value of electrical conductivity.

LEVEL_SET

Name of the model for constant electrical conductivity.Allows for the conductivity as a function of the level-set field. Specifically used for changing the conductivity from one constant value on the negative side of the interface to another constant value on the positive side. The model requires three floats:

  • <float1> - the value of electrical conductivity in the negative regions of the level set function.

  • <float2> - the value of electrical conductivity in the positive regioons of the level-set function.

  • <float3> Length scale over which the transition occurs. If this parameter is set to zero, it will default to one-half the Level-Set Length Scale value specified.

ELECTRONEUTRALITY_FICKIAN

Name of the model for the electrical conductivity. This model requires no parameter specification, i.e. no floats.

ELECTRONEUTRALITY_SM

Name of the model for the electrical conductivity. This model requires no parameter specification, i.e. no floats.

In earlier versions of Goma, this model was referred to by the name ELECTRODE_KINETICS and it remains to be active so that Goma can be backward compatible. In other words, ELECTRONEUTRALITY_SM and ELECTRODE_KINETICS are interchangeable.

See Technical Discussion for information on the electrical conductivity for the two models of ELECTRONEUTRALITY.

Examples

Following are sample cards:

Electrical Conductivity = CONSTANT 1.
Electrical Conductivity = ELECTRONEUTRALITY_FICKIAN
Electrical Conductivity = ELECTRONEUTRALITY_SM
Electrical Conductivity = ELECTRODE_KINETICS

Technical Discussion

For concentrated electrolyte solutions in which Stefan-Maxwell flux equations are employed to relate species fluxes to concentrations and their gradients, the electrical conductivity is given by (Chen et al. 2000, Schunk et al. 2000):

../_images/399_goma_physics.png

where i = m(i’ – 1) + 1 and k = m(k’ – 1) + 1, m is dimension of the problem (m = 2 for a 2-D problem), and is species mole fraction. The tedious definition of can be found in Chapter 2 of Chen et al. (Chen et al. 2000) and in Chapter 7 of the Goma Developer’s Guide (Schunk, et. al., 2000).

For dilute electrolyte solutions in which Fick’s first law is used to relate the flux of a species to its concentration gradient, the electrical conductivity is given by (Chen, 2000; Schunk, et. al., 2000):

../_images/400_goma_physics.png

where ci is the molar concentration and zi is the charge number of species i, respectively; and n is the total number of species present in the electrolyte solution. Note that the nth species is taken to be the neutral solvent species, which has no contribution to the electrical conductivity since its charge number is zero.

Lastly, Goma calculates the conductivity in function assemble_potential as material properties are being loaded.

References

GTM-025.0: Chen, K. S., “Modeling diffusion and migration transport of charged species in dilute electrolyte solutions: GOMA implementation and sample computed predictions from a case study of electroplating”, Sandia technical memorandum, September 21, 2000.

SAND2000-0207: Chen, K. S., Evans, G. H., Larson, R. S., Noble, D. R., and Houf, W. G., “Final Report on LDRD Project: A Phenomenological Model for Multicomponent Transport with Simultaneous Electrochemical Reactions in Concentrated Solutions”, Sandia Technical Report, 2000.

GDM-1.3: Schunk, P. R., Sackinger, P. A., Rao, R. R., Subia, S. R., Baer, T. A., Labreche, D. A., Moffat, H. K., Chen, K. S., Hopkins, M. M., and Roach, R. A., “GOMA 3.0 - A Full-Newton Finite Element Program for Free and Moving Boundary Problems with Coupled Fluid/Solid Momentum, Energy, Mass, and Chemical Species Transport: Developer’s Guide, 2000.

Electrical Permittivity

Electrical Permittivity = {model_name} {float} []

Description / Usage

This required card is used to specify the model for electrical permittivity. There is currently one option, so {model_name} must be either CONSTANT. Definitions of the input parameters are as follows:

CONSTANT

Name of the model for constant electrical permittivity.

  • <float> -the value of electrical permittivity.

Examples

Following are sample cards:

Electrical Permittivity = CONSTANT 1.

Technical Discussion

This card is utilized to set the electrical permittivity for electrostatic problems.

References